Measure Type | High Priority Measure? | Collection Type(s) |
---|---|---|
Efficiency | yes | MIPS CQM |
Measure Description
Percentage of all stress single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), stress echocardiogram (ECHO), cardiac computed tomography angiography (CCTA), and cardiovascular magnetic resonance (CMR) performed in patients aged 18 years and older routinely after percutaneous coronary intervention (PCI), with reference to timing of test after PCI and symptom status
Instructions
This measure is to be submitted once per procedure of cardiac stress imaging (i.e., SPECT, MPI, ECHO, CCTA and CMR) for patients seen during the performance period. There is no diagnosis associated with this measure. It is anticipated that eligible clinicians who provide the professional component of diagnostic imaging studies for cardiac stress will submit this measure.
Measure Submission Type:
Measure data may be submitted by individual MIPS eligible clinicians, groups, or third party intermediaries. The listed denominator criteria are used to identify the intended patient population. The numerator options included in this specification are used to submit the quality actions as allowed by the measure. The quality-data codes listed do not need to be submitted by MIPS eligible clinicians, groups, or third party intermediaries that utilize this modality for submissions; however, these codes may be submitted for those third party intermediaries that utilize Medicare Part B claims data. For more information regarding Application Programming Interface (API), please refer to the Quality Payment Program (QPP) website.
Denominator
All instances of stress single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), stress echocardiogram (ECHO), cardiac computed tomography angiography (CCTA), or cardiac magnetic resonance (CMR) performed on patients aged 18 years and older during the submission period
Denominator Criteria (Eligible Cases):
Patients aged ≥ 18 years on date of encounter
AND
Cardiac Stress Imaging Performed – Procedure Codes (CPT): 75559, 75563, 75571, 75572, 75573, 75574, 78451, 78452, 78453, 78454, 78491, 78492, 78494, 93350, 93351
Numerator
Number of stress SPECT MPI, stress echo, CCTA and CMR performed in asymptomatic patients within 2 years of the most recent PCI
Numerator Instructions:
INVERSE MEASURE – A lower calculated performance rate for this measure indicates better clinical care or control. The “Performance Not Met” numerator option for this measure is the representation of the better clinical quality or control. Submitting that numerator option will produce a performance rate that trends closer to 0%, as quality increases. For inverse measures, a rate of 100% means all of the denominator eligible patients did not receive the appropriate care or were not in proper control.
NUMERATOR NOTE: A lower calculated performance rate for this measure indicates better clinical care or control. This measure is assessing overuse of cardiac stress imaging in asymptomatic patients that received PCI. Clinical quality outcome is cardiac stress imaging NOT performed on patient who is asymptomatic or low CHD risk.
Numerator Options:
Performance Met:
Cardiac Stress Imaging performed primarily for monitoring of asymptomatic patient who had PCI within 2 years (G8963)
OR
Performance Not Met:
Cardiac Stress Imaging test performed primarily for any other reason than monitoring of asymptomatic patient who had PCI within 2 years (e.g., symptomatic patient, patient greater than 2 years since PCI, initial evaluation, etc.) (G8964)
Stay updated with the latest news regarding MACRA and MIPS
The Healthmonix Advisor is a free news source that connects you to the latest in the value-based care industry!